Command Reference Guide Line (Console) Interface Config Command Set
61950860L1-35D © 2003 ADTRAN, Inc. 525
stopbits <option>
Use the stopbits command to set the number of stopbits per character for a terminal session. This value
must match the configuration of your VT100 terminal or terminal emulator software. The default is 1
stopbit per character. Use the no form of this command to return to the default value.
Syntax Description
<option>
Specifies the number of stopbits per character
1
1 stopbit
2
2 stopbits
Default Values
<option> 1
Command Modes
(config-con 0)# Console Interface Configuration Mode required
Command History
Release 1.1 Command was introduced
Usage Examples
The following example configures 2 stopbits per character for the console terminal session:
(config)#
line console 0
(config-con 0)#
stopbits 2