Ethernet Tools
210 AXS-200/805/855
Cable Test Results - Wire Map
³ Fault Dist. (m/ft): Gives the distance to fault from the near end for
each pair, unless the problem is due to excessive noise. Noise may be
due to electrical noise causing communication error.
Note: When no value is available, --” is displayed.
³ The Pass/Fail verdict is also displayed for each pair when enabled. To
enable the Pass/Fail verdict, see Pass/Fail Verdict on page 202.
= PASS
= FAIL
If the determined Wire Map is either MDI, MDIX, MDI (-), MDIX (-), or
Noise (Link up), the test is declared as PASS. If the determined Wire
Map is either Short, Short-between-pair, Open, Noise (Link down), or
Unknown, the test is declared as FAIL.