Ethernet Traffic Generation & Monitoring Test
168 AXS-200/805/855
Throughput Results
Throughput Results
Press , select ETHERNET, Traffic Generation & Monitoring, Results,
and the Throughput tab.
³ TX Rate: Displays the
transmission rate in terms of a
percentage of the line rate or
Mbps. The transmit rate is
displayed individually for main
stream and each background
stream.
³ RX Rate: Displays the receive rate
in terms of a percentage of the
line rate or Mbps. The receive
rate is displayed individually for main stream and each background
stream.
³ Current: Displays average RX rate value of the last second.
³ Average: Displays average RX rate value from the beginning of the
test.
³ Minimum: Displays minimum RX rate value from the beginning of
the test.
³ Maximum: Displays maximum RX rate value from the beginning of
the test.
³ Threshold Min: Set the minimum threshold value. The accepted range
is 0.0 to 100.0 in percentage (0 to 10 in Mbps). The default value in
percentage is 0.0 and in Mbps is 0.
³ Threshold Max: Set the maximum threshold value. The accepted
range is 0.0 to 100.0 in percentage (0 to 10 in Mbps). The default value
in percentage is 100.0 and in Mbps is 10.