Ethernet Traffic Generation & Monitoring Test
Multi Protocol Test Set 143
Sequence Configuration
³ Out of Sequence Pass/Fail Verdict: Select the type of verdict for
declaring the number of frames that went out of sequence. Choices
are Count, Rate, and Disabled.
Threshold: Set the threshold value for declaring number of frames that
went out of sequence. The Out-Of-Sequence Pass/Fail verdict is
declared as PASS when the count or rate value is smaller than or equal
to the threshold. The Out-Of-Sequence Pass/Fail verdict is declared as
FAIL when the count or rate value is greater than the threshold.