Ethernet Test Setup
48 AXS-200/805/855
Port
7. Set the Flow Control. This option is applicable to the RFC 2544 test
and Traffic Generation test. Flow Control is not supported (set to
None) for BERT and Smart Loopback tests. When Flow Control is
enabled, the AXS-200/855 will stop transmitting for the requested time
value specified by the valid flow control frame received. The choices
are None,andRX. The default setting is None. When set to None,
pause frames received are ignored.
Note: For Auto, the negotiated flow control is displayed besides the flow control
configuration parameter.
8. Frequency: Indicates the frequency of the input signal in Mbps. When
no frequency reading is possible, “--” is displayed.