ADTRAN Stub Routing Guide de l'utilisateur Page 55

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 132
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 54
Table 3: show interfaces Fast Ethernet Output Fields (continued)
Level of OutputField DescriptionField Name
extensive(10-Gigabit Ethernet interfaces, WAN PHY mode) Active alarms and defects,
plus counts of specific SONET errors with detailed information.
Seconds—Number of seconds the defect has been active.
Count—Number of times that the defect has gone from inactive to active.
State—State of the error. Any state other than OK indicates a problem.
Subfields are:
BIP-B3—Bit interleaved parity for SONET section overhead
REI-P—Remote error indication
LOP-P—Loss of pointer (path)
AIS-P—Path alarm indication signal
RDI-P—Path remote defect indication
UNEQ-P—Path unequipped
PLM-P—Path payload (signal) label mismatch
ES-P—Errored seconds (near-end STS path)
SES-P—Severely errored seconds (near-end STS path)
UAS-P—Unavailable seconds (near-end STS path)
SES-PFE—Severely errored seconds (far-end STS path)
UAS-PFE—Unavailable seconds (far-end STS path)
WIS path
43Copyright © 2013, Juniper Networks, Inc.