Option Modules NetVanta 6310/6330 Series Hardware Installation Guide
36 Copyright © 2013 ADTRAN, Inc. 61700100G1-34F
NetVanta Quad FXS/FXO VIM2 (P/N 1700111G1)
The NetVanta Quad FXS/FXO VIM2 (see Figure 17) adds voice capability to the NetVanta 6310/NetVanta
6330 Series. See Table A-12 on page 46 for the FXS/FXO connector pinouts.
Figure 17. NetVanta Quad FXS/FXO VIM2
FXS
1
234
FXO
1
234
Features and Specifications
Analog Voice Ports
Four FXS ports
Four FXO ports
Loop Start (LS), Ground Start (GS)
Normal and reverse battery operation
Transmission Level
FXS Receive Gain: -12 to +6 dB,
0.1 dB steps
FXS Transmit Gain: -12 to +6 dB,
0.1 dB steps
FXO Receive Gain: -6 to +10 dB,
0.1 dB steps
FXO Transmit Gain: -6 to +10 dB,
0.1 dB steps
Impedance
FXS: 600 , 600 +2.16 F, 900 ,
900 +2.16 F
FXO: 600 , 600 +2.16 F, 900 ,
900 +2.16 F, Rs 220 , Rp 820,
Cp 115 nF, Rs 270 , Rp 750,
Cp 150 nF, Rs 270 , Rp 750,
Cp 150 nF, Zin 600r, Rs 320 ,
Rp 1050 , Cp 230 nF, Rs 350 ,
Rp 1000 , Cp 210 nF, Zin 600r,
Rs 370 , Rp 620, Cp 310 nF, Rs 800 ,
Rp 100, Cs 50 nF
Port Tests
1 kHz test tone (near-end, far-end
selectable)
FXS: Reverse polarity, active, ringing,
tip-open
FXO: Loop open, loop closed, ring ground
FXS: Loopbacks: Analog and digital
Compliance
EMC - see Electromagnetic Compatibility
(EMC) Table on page 6.
UL/CUL 60950-1
ACTA/FCC Part 68
IC CS-03
RoHS compliant (Telecommunications
exemption)
Environmental
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95 percent,
noncondensing
Physical
Dimensions: 4.25-inch W x 4.25-inch D