Chapter 5 Config Menu TSU LT 220V User Manual
40 © 2004 ADTRAN, Inc. 61203060L2-1A
PORT MENU
Use this menu to select and configure the parameters associated with the V.35 port.
TEL NUM
Sets the telephone number to be dialed to send alarm traps. The string can be up to 20
characters in length and is terminated with a semicolon (;) as the last character. A
colon (:) character is used to represent a pause in the dial string.
For example, for number 9:5551212; dial 9, pause momentarily and then dial
5551212. This pause could be necessary to access an outside line, such as a PBX.
When editing a specific character, the arrows are used to scroll from 0 to 9, then colon
(:) and semicolon (;). The new telephone number is entered into the TSU LT 220V
only after typing the semicolon and pressing
ENTER.
Choices: 20 digits (
0-9, :, and ;)
The ALARM > TEL NUM menu only accepts the typed digits after pressing ENTER.
RATE 56/64
Sets the base rate of the interface. The actual data rate depends on the number of
DS0s assigned to the Nx port. The DTE data rate versus the number of DS0s appears
in Appendix B, DTE Data Rate Chart, on page 53.
Choices: 56K, 64K
CHANNELS
Sets the unit to use ALTERNATE or CONTIGUOUS channels in the T1 data stream. If
more than 12 channels are used, then
CONTIGUOUS must be used. Otherwise,
ALTERNATE channels may be used to meet pulse density requirements (this is only
necessary for Nx 64 without B8ZS). If other than a private network, the carrier must
be notified of this choice.
Choices: ALT (alternate), CONT (contiguous)
DTE TX CLK
Controls the clock used by the TSU LT 220V to accept the transmit (TX) data from
the DTE. Most applications will allow for this to be set to
INTERNAL. If the interface
cable is long (causing a phase shift in the data) the clock can be selected as
INT-INV
(Internal/Inverted - the factory default setting). This switches the phase of the clock,
which should compensate for a long cable.
The
AUTO setting allows the TSU LT 220V to automatically detect the delay from
the DTE device to the TSU LT 220V and set the proper phase of the clock. This
feature automatically selects between the
INTERNAL and INT-INV settings. If the DTE
provides a clock with TX data, the clock selection is set to
EXTERNAL. The TSU LT
220V depends on an externally supplied clock to accept the TX data.
Choices: INT-INV, INTERNAL, EXTERNAL, AUTO