61203060L2-1A © 2004 ADTRAN, Inc. 23
Chapter 3 Operation
FRONT PANEL
The front panel monitors operation and controls the unit configuration. Figure 3-1 illustrates the
TSU LT 220V front panel. Use the Up and Down arrows on the front panel to access the menus and data
fields. At every menu level, pressing
CANCEL returns the system to the previous menu level. Repeatedly
pressing
CANCEL returns the system to the main menu. Table 3-1 lists the unit features identified by number
in Figure 3-1.
Figure 3-1. TSU LT 220V Front Panel
Table 3-1. Number Identification for TSU LT 220V Front Panel
Item Displays Function
1PWR
LED ON when power is received by the TSU LT 220V.
2 ERR LED ON when error event occurred in the last second (for example, BPV).
3 ALM LED ON when an alarm condition exists.
4 TST LED ON when unit is in test mode.
5 TD LED ON when DTE data is being transmitted.
6 RD LED ON when DTE data is being received.
7 RS LED ON when request to send (RTS) active from DTE.
8CS
LED ON when TSU LT 220V has clear to send (CTS) active toward DTE.
9LCD
A 2X16 LCD window that displays menu items used in configuration and
displays information useful in monitoring the unit. See also LCD Window on
page 24.
PWR
ERR
ALM
TST
TD
CS
RS
112
11 10 9
63524 78