Configuring Static Routes
BlueSecure™ Controller Setup and Administration Guide 4-29
To enable outbound administrator traffic from the Admin interface, a static route must be
configured. This is required because the BSC has a separate routing table for the Admin
interface than the rest of the box. Rarely, you may need to add a static route to a special
network destination that is not normally included in the routing table.
Caution: This is an advanced BSC configuration function. Do not add static routes unless
you have a thorough understanding of network and routing concepts.
To add a static route to the BSC routing table:
1. Click the Network tab in the BSC administrator console, and then click the Routing
Table tab on the Network page.
2. Select Static Route Entry from the Create drop-down list on the Network page.
The Create a static route entry page appears as shown in Figure 4-22.
3. Enter the IP address of the destination network in the Route Destination field.
Figure 4-21: Sample BSC Routing Table
Figure 4-22: Create a Static Route Entry