ADTRAN 1200080L1#HS Manuel d'utilisateur Page 20

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 38
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 19
Chapter 3. Operation
16 FXS+ Dual Voice Option Module 61200.080L1-1
2W STATUS (2-Wire Status)
There are three information fields, Busy, Ringing, and
MW (message waiting). See Figure 3-3. An asterisk (*)
indicates an item is active.
Figure 3-3
2-Wire Status Display
Busy
An asterisk is present if loop current is flowing through
the 2-wire circuit.
Ringing
An asterisk is present if ringing voltage is being applied
to the 2-wire circuit from the ring-generator on the FXS+
option module.
Message Waiting (MW)
An asterisk is present if the card is in the message-
waiting mode and is receiving commands from the far
end FXO+ to turn on the message-waiting light
VIEW SIG BITS (View Signaling Bits)
View Sig Bits is used to view the status of the RX and TX
signaling bits in the DS-1 stream. See Figure 3-4. The
status of both the A and B bits is displayed.
Figure 3-4
View Signaling Bits Display
Vue de la page 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 37 38

Commentaires sur ces manuels

Pas de commentaire