Total Access 1240 Installation and Maintenance Practice
B-4 61179605L5-5B
:LocSTULineProvisioning 24 (Values are in Hex)
: LocSTULineProvisioning 24 Internal Variable Name (Do not Change)
C: 1| 2| 3| 4| 5| 6| 7| 8| 9| A| B| C| D| E| F| 10| 11|
12| 13| 14| 15| 16| 17| 18| 19| 1A| 1B| 1C| 1D| 1E| 1F| 20| 21| 22|
23| 24| 25| 26| 27
Column Header (Do not Change)
-----------------------------------------------------------------------------------
-----------------------------------------------------------------------------------
----------------------------
Column Separator (Do not Change)
26, 0, 0, 0, 0, 0, 1, 0, 0, 0, 2, 0, 20, 20, 20, 0, 0,
0, 0, 0, 0, e, 12, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0,
0, 0, 0, 0, ad
See Table B-5 below by column number
...
Table B-4. LocSTUCardProvisioning
Column Option Values
1 Number of Options Do not change
2 Card Service State 0 = SERVICE_STATE_IN_SERVICE
1 = SERVICE_STATE_OOS_UNASSIGNED
2 = SERVICE_STATE
3 Powerdown Timeout 0 = Disabled
1 to 999 = timeout in minutes
4 Fan Alarm Delay 0 = Disabled
1 to 15 = delay in minutes
5 - 8 RESERVED for Future Use
Table B-5. LocSTULineProvisioning
Column Option Values
1 Number of options Do not change
2 Line Service State 0 = SERVICE _STATE_IN_SERVICE
1 = SERVICE_STATE_OOS_UNASSIGNED
2 = SERVICE_STATE_OOS_MAINTENANCE
3 SHDSL SNR Margin Alarm
Threshold
0 = Disabled
1 to 15 = threshold in dB
4 SHDSL Loop Attenuation Alarm
Threshold
0 = Disabled
1 to 127 = threshold in dB
5 SHDSL Loopback Timeout 0 = Disabled
1 to 4096 = timeout in minutes
6 Unit Mode 0 = STUC
1 = STUR