ADTRAN HDSL4 Spécifications

Naviguer en ligne ou télécharger Spécifications pour Mise en réseau ADTRAN HDSL4. ADTRAN HDSL4 Specifications Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 26
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Section 61223424L2-5A
Issue 1, December 2003
CLEI Code: T1L497PC_ _
61223424L2-5A 1
Trademarks: Any brand names and product names included in this document are
trademarks, registered trademarks, or trade names of their respective holders.
CONTENTS
1. General...................................................................................... 1
2. Installation ................................................................................ 2
3. Connections .............................................................................. 5
4. HDSL4 System Testing ............................................................ 5
5. Front Panel Operation............................................................... 7
6. Control Port Operation.............................................................. 7
7. HDSL4 Deployment Guidelines ............................................. 18
8. Maintenance............................................................................ 23
9. Specifications.......................................................................... 23
10. Warranty and Customer Service ............................................. 23
Appendix A. HDSL4 Loopbacks.............................................. A-1
TABLES
Table 1. ADTRAN Unit Compatability........................................ 1
Table 2. H2TU-R Enclosure Compatibility .................................. 2
Table 3. Compliance Codes .......................................................... 2
Table 4. Front Panel Indicators ..................................................... 3
Table 5. Provisioning Options ...................................................... 4
Table 6. Attenuation limits ......................................................... 18
Table 7. Range Limits: 26 Gauge / 70°F / PIC .......................... 18
Table 8. Range Limits: 24 Gauge / 70°F / PIC .......................... 18
Table 9. Single Pair DC Resistance Value.................................. 19
Table 10. HDSL4 Insertion Loss Values ...................................... 22
Table 11. Single Span and First Segment of Repeatered Loop .... 22
Table 12. Second or Third Segment of Repeatered Loop............. 22
Table 13. Troubleshooting Guide ................................................. 23
Table 14. HDSL4 T200 H4TU-R Specifications.......................... 24
Table A-1. HDSL4 Loopback Control Codes............................ A-2
Table A-2. Loopback Control Codes ......................................... A-3
1. GENERAL
The ADTRAN 4-wire T200 HDSL4 transceiver unit for
the remote end (H4TU-R), P/N 1223424L2, is a
network terminating unit used to deploy an HDSL4 T1
circuit using 4-wire metallic facilities. See Figure 1.
This version of the H4TU-R works with multiple list
versions of the HDSL4 transceiver unit for the central
office (H4TU-C) and repeater (H4R) as listed in
Table 1.
Revision History
This is the initial release of this document. Future
revisions to this document will be explained in this
subsection.
Figure 1. ADTRAN HDSL4 T200 H4TU-R
NOTE: x = any generic release number
Table 1. ADTRAN Unit Compatability
Unit Number Description
122x401L1 or L2 220 H4TU-C
122x403L1 or L2 DDM+ H4TU-C
122x404L1 or L2 3192 H4TU-R
118141xL1 Total Access H4TU-C
122x441L1 T200 H4R
122x445L1 239 H4R
TX
R
X
REM
LOC
LBK
1223424L2
LOCAL
DSL 1
DSL 2
DS1
ALM
(GRN)
SF
(YEL)
ESF/
(GRN)
AMI
(YEL)
B8ZS
/
(GRN)
RLB
(YEL)
LLB
/
RX
M
O
N
TX
R
S
2
3
2
HDSL4 T200 H4TU-R
Installation and Maintenance Practice
Vue de la page 0
1 2 3 4 5 6 ... 25 26

Résumé du contenu

Page 1 - HDSL4 T200 H4TU-R

Section 61223424L2-5AIssue 1, December 2003CLEI Code: T1L497PC_ _61223424L2-5A 1Trademarks: Any brand names and product names included in this doc

Page 2

10 Issue 1, December 2003 61223424L2-5AThe Detailed Status Screen from the Span Status menu (Figure 10), displays the HDSL4 status for each receiv

Page 3 - Front Panel LED Indicators

61223424L2-5A Issue 1, December 2003 11The Performance History screens (Figure 12 and Figure 13) are used to select and display the historical HDS

Page 4 - Latching Loopback Mode

12 Issue 1, December 2003 61223424L2-5AAbbreviations used in the Performance History screens are defined in Performance Data Definitions screens (

Page 5

61223424L2-5A Issue 1, December 2003 13The Scratch Pad, Circuit ID, and Time/Date Screen (Figure 16) provides a Scratch Pad for user-defined infor

Page 6

14 Issue 1, December 2003 61223424L2-5AThe Event History screen (Figure 19) provides a log history of HDSL4 circuit events.Figure 18. HDSL4 Span

Page 7 - Main Menu is presented as

61223424L2-5A Issue 1, December 2003 15The System PM/Screen Report option (Figure 20) offers four types of reports on performance monitoring. Sele

Page 8 - Main Menu provides access to

16 Issue 1, December 2003 61223424L2-5AItem 12 on the Main Menu displays the Troubleshooting screen (Figure 22). Helpful ADTRAN contact infor-mati

Page 9

61223424L2-5A Issue 1, December 2003 17Selecting option 2 from the Troubleshooting screen accesses the General Information Screen (Figure 24) that

Page 10

18 Issue 1, December 2003 61223424L2-5A7. HDSL4 DEPLOYMENT GUIDELINESThe different segments of an HDSL4 circuit are defined in Figure 26.Figure 26

Page 11

61223424L2-5A Issue 1, December 2003 198. MAINTENANCEThe T200 H4TU-R requires no routine maintenance for normal operation. In case of equipment ma

Page 12 - Performance History screens

2 Issue 1, December 2003 61223424L2-5ADescriptionThe T200 H4TU-R can be deployed in circuits using one H4TU-C, one H4TU-R, and up to two H4Rs. The

Page 13 - Span History

20 Issue 1, December 2003 61223424L2-5ATable 10. HDSL4 T200 H4TU-R SpecificationsSpecification DescriptionLoop InterfaceModulation TypeModeNumber

Page 14

61223424L2-5A A-1HDSL4 MAINTENANCE MODESThis appendix describes operation of the HDSL4 system with regard to detection of inband and ESF facility data

Page 15

A-2 Issue 1, December 2003 61223424L2-5A1. The Source column indicates from which side of the interface the control codes are sent. For example, an (N

Page 16 - Troubleshooting screen

61223424L2-5A Issue 1, December 2003 A-3Table A-2. Loopback Control CodesFunction Code (Hex / Binary) ResponseARM (in-band) - also known as 2-in-5 pa

Page 17 - CTRL+X to terminate

A-4 Issue 1, December 2003 61223424L2-5A1. Units must be armed with 11000b or FF48h before this code will work. 2. Loopback and error injection will o

Page 18

61223424L2-5A Issue 1, December 2003 A-5This page is intentionally blank.

Page 19

A-6 Issue 1, December 2003 61223424L2-5A

Page 20

61223424L2-5A Issue 1, December 2003 3Front Panel LED IndicatorsThere are seven front panel mounted status LED indicators. Each indicator is descr

Page 21 - HDSL4 Loopbacks

4 Issue 1, December 2003 61223424L2-5ARemote ProvisioningThere are no configuration switches for the T200 H4TU-R. Configuration is performed via s

Page 22

61223424L2-5A Issue 1, December 2003 53. CONNECTIONSAll connections of the T200 H4TU-R are made through card edge connectors. Figure 2 gives the c

Page 23

6 Issue 1, December 2003 61223424L2-5AH4TU-R Network LoopbacksThe loopback position is a logic loopback located within the H4TU-R internal HDSL4 t

Page 24

61223424L2-5A Issue 1, December 2003 75. FRONT PANEL OPERATIONThe front panel contains two pushbuttons. These are labeled LOC and REM.The LOC push

Page 25

8 Issue 1, December 2003 61223424L2-5AThis ADTRAN HDSL4 Main Menu provides access to detailed performance and configuration information. The OAM&a

Page 26

61223424L2-5A Issue 1, December 2003 9The Provisioning menu (Figure 8) displays current provisioning settings for the HDSL4 circuit. Options that

Commentaires sur ces manuels

Pas de commentaire